Trace Elements
Iron (Fe)
The iron and total iron binding capacity (TIBC) levels are influenced by changes in iron intake, absorption, storage, and release mechanisms. Such changes are indicative of a wide range of dysfunctions including anemias, nephrosis, cirrhosis and hepatitis. Iron measurements are interrelated parameters for the diagnosis of the iron status.
Colorimetric test for the quantitative determination of iron in human serum and heparinised plasma.
TPTZ reagents
Kit name | Reagent type | Size | REF |
---|---|---|---|
Iron TPTZ liquicolor | Multipurpose reagent | 2 x 25 ml | 12290 |
Iron TPTZ liquicolor | Multipurpose reagent | 2 x 100 ml | 12291 |
Iron TPTZ liquicolor | System reagent for | 2 x 100 tests | 12290300 |
Iron TPTZ liquicolor | System reagent for | 2 x 180 tests | 12290600 |
CAB reagents
Kit name | Reagent type | Size | REF |
---|---|---|---|
Iron liquicolor | Multipurpose reagent | 2 x 30 ml | 10229 |
Iron liquicolor | Multipurpose reagent | 2 x 100 ml | 10230 |
Related products
Magnesium (Mg)
Magnesium measurements are used in the diagnosis and treatment of hypo- and hypermagnesemia. When making clinical assessment of magnesium levels the calcium levels should also be considered. The best-defined manifestation of magnesium deficiency is impairment of neuromuscular function e.g. hyperirritability, tetany, convulsions, and electrocardiographic changes.
- Hypomagnesemia: Observed in diabetes, chronic alcoholism, forced diuresis, hyperthyroidism, hypoparathyroidism, hypocalcemia, malabsorption and acute pancreatitis.
- Hypermagnesemia: Increased serum magnesium levels have been found in cases of renal failure, dehydration, severe diabetic ketoacidosis and Addison's disease.
Colorimetric test for the quantitative determination of magnesium in human serum and plasma (no EDTA plasma).
Kit name | Reagent type | Size | REF |
---|---|---|---|
Magnesium liquicolor | Multipurpose reagent | 2 x 100 ml | 10010 |
Magnesium liquicolor | System reagent for | 4 x 30 tests | 10010300 |
Magnesium liquicolor | System reagent for | 4 x 60 tests | 10010600 |
Related products
Total Iron Binding Capacity (TIBC)
The iron and total iron binding capacity (TIBC) levels are influenced by changes in iron intake, absorption, storage, and release mechanisms. Such changes are indicative of a wide range of dysfunctions including anemias, nephrosis, cirrhosis and hepatitis. Iron and TIBC measurements are interrelated parameters for the diagnosis of the iron status.
Saturation and absorbant reagents for sample preparation for the determination of total iron binding capacity (TIBC) in human serum or heparinised plasma.
Kit name | Reagent type | Size | REF |
---|---|---|---|
TIBC | Multipurpose reagent | 1 x 100 tests | 10670 |