SIEMENS ADVIA Centaur СP or HumaCLIA 150: Which Immunoassay Analyzer To Choose?

Chemiluminescence immunoassay (CLIA) analyzers such as the HumaCLIA 150 and ADVIA Centaur СP offer advanced features and capabilities to meet the diverse needs of today's diagnostic laboratories. Understanding the specific benefits of each model can help you select the optimal instrument for your laboratory's needs.

 

Company HUMAN SIEMENS
Model HumaCLIA 150 ADVIA Centaur CP
Type of Instrument Benchtop Benchtop
Mode Continuous access Continuous access
Detection based on Acridinium ester (AE) Acridinium ester (AE)
Throughput (up to) 150 t/h 180 t/h
Assay time approx. 30 min 42 or 72 min
Reagent positions 20 refrigerated 15
Sample positions 50 84
STAT positions (Emergency samples) 50 1
Reaction cuvettes onboard capacity 1000 cuvettes 400 cuvettes
Cuvette format Single cuvettes in bulk format Single cuvettes in bulk format

*All information is correct as of March 2024

 

 

Selecting the right immunoassay analyzer can significantly enhance laboratory efficiency and accuracy. This comparison between the HUMAN HumaCLIA 150 and SIEMENS ADVIA Centaur CP highlights their key features to help you decide which one best meets your laboratory needs.

Type of Instrument

The type of instrument determines the space requirements and suitability for different laboratory setups. Both the HumaCLIA 150 and the ADVIA Centaur CP are benchtop analyzers designed for continuous access operation, allowing for uninterrupted addition of samples, reagents, and consumables to enhance workflow efficiency.

HumaCLIA 150: Ideal for laboratories with limited space needing high-performance analyzers.

ADVIA Centaur CP: Suitable for small to medium-sized laboratories requiring a versatile and compact analyzer.

Mode

The operational mode affects how samples and reagents are processed during the testing workflow. Both analyzers operate in continuous access mode, which provides consistent processing capability and accommodates varying sample volumes seamlessly.

HumaCLIA 150: Allows for uninterrupted sample and reagent addition, enhancing workflow efficiency.

ADVIA Centaur CP: Provides consistent processing capability, accommodating varying sample volumes seamlessly.

Detection Based On

The detection method is critical for sensitivity and specificity, impacting the accuracy of test results. Both analyzers utilize Acridinium Ester (AE) for detection, a chemiluminescent substrate known for its high sensitivity and specificity.

HumaCLIA 150: Utilizes Acridinium Ester (AE) for detection.

ADVIA Centaur CP: Utilizes Acridinium Ester (AE) for detection.

Throughput (up to)

Throughput capacity is essential for laboratories that handle high sample volumes, as it determines how many tests can be processed within a given timeframe.

HumaCLIA 150: Offers a maximum throughput of 150 tests per hour, making it suitable for high-volume testing environments.

ADVIA Centaur CP: Provides a higher throughput of 180 tests per hour, ideal for laboratories with very high sample volumes.

Assay Time

Assay time affects the speed at which individual tests are completed, influencing overall laboratory throughput and efficiency.

HumaCLIA 150: Has an approximate assay time of 30 minutes, providing a balance between rapid processing and detailed analysis.

ADVIA Centaur CP: Offers assay times of 42 or 72 minutes, which might be longer but can be suitable for specific testing requirements that necessitate extended analysis times.

Reagent Positions

The availability of reagent positions plays a critical role in supporting laboratories performing a wide range of tests. An increased number of reagent positions allows for greater testing flexibility and reduces the need for frequent reagent changes.

HumaCLIA 150: Equipped with 20 refrigerated reagent positions, providing versatility in conducting a diverse range of tests and minimizing the need for frequent reagent changes.

ADVIA Centaur CP: Features 15 reagent positions, offering sufficient capacity for a variety of assays and efficient reagent management.

Sample Positions

Adequate sample positions are crucial for managing sample volumes effectively, preventing backlogs, and maintaining smooth laboratory operations.

HumaCLIA 150: Provides 50 sample positions, catering to higher sample volumes and including provisions for urgent STAT samples.

ADVIA Centaur CP: Offers 84 sample positions, effectively managing larger sample volumes and ensuring operational efficiency.

STAT Positions (Emergency Samples)

Handling STAT (emergency) samples efficiently is vital for clinical laboratories, ensuring priority processing without disrupting routine workflows.

HumaCLIA 150: Integrates STAT sample handling within its 50 sample positions, allowing for seamless inclusion of urgent tests in the workflow.

ADVIA Centaur CP: Includes 1 dedicated STAT position, ensuring that emergency samples are processed promptly, which is crucial for urgent diagnostic needs.

Reaction Cuvettes Onboard Capacity

The onboard capacity of reaction cuvettes affects how long the analyzer can operate without needing cuvette replacement, impacting efficiency and workflow continuity.

HumaCLIA 150: Boasts a substantial onboard capacity of 1000 reaction cuvettes, supporting extended continuous operation and reducing the frequency of interruptions for cuvette replacement.

ADVIA Centaur CP: Features an onboard capacity of 400 cuvettes, which may require more frequent replacements but supports efficient test processing for moderate to high sample volumes.

Cuvette Format

The format of cuvettes can influence the ease of use, operational efficiency, and cost-effectiveness of the analyzer. Both analyzers use single cuvettes in bulk format, which is advantageous for high-volume testing environments due to easier handling and lower costs.

HumaCLIA 150: Uses single cuvettes in bulk format.

ADVIA Centaur CP: Uses single cuvettes in bulk format.

Conclusion

The choice between the HumaCLIA 150 and ADVIA Centaur CP should be based on the specific priorities and requirements of your laboratory. Considerations include testing volume, reagent and sample capacity, STAT sample handling, assay time, and cuvette management. By evaluating these factors, laboratories can make a well-informed decision that aligns with their operational needs and testing demands.

 

Use the following form for any request whether it is product related or concerning potential distribution partnership.